Nutanix network segmentation

By default, every Nutanix CVM sends almost all of its external traffic through one interface, eth0. Prism, SSH, storage replication between nodes, iSCSI to external clients, and replication to a DR site all leave through it, on the management VLAN. For many customers that’s fine. For others, usually because of a security or compliance requirement, it isn’t. Network segmentation is how Nutanix splits that traffic onto separate VLANs, and even separate physical NICs.

A few weeks ago I wrote about one real case: isolating Nutanix Volumes iSCSI traffic for an OpenShift cluster. Now I’m preparing backplane segmentation for a customer with two clusters. While reading the AOS Security Guide line by line for that change, I decided to write the full picture in one place: what segmentation is, every type, on both AHV and ESXi, with the steps, the commands, and the impact of each.

One detail changes the whole plan, and it’s easy to miss: on AHV, enabling the backplane network needs a full guest VM shutdown. On ESXi it doesn’t, and the service-specific types don’t on either hypervisor. If you’re about to promise a customer “a rolling change with no downtime”, read the impact section first.

The post is long, so here’s the map:

Section What it covers
Understanding Network Segmentation The concepts: traffic types, interfaces, logical and physical, AHV and ESXi
Choosing, impact, prerequisites, common steps What to pick, what it costs, what to prepare
Part 1: Backplane Replication, HA and live migration on their own network
Part 2: Volumes iSCSI to external clients on its own network
Part 3: Disaster recovery Replication between sites on its own network
Part 4: RDMA Stargate-to-Stargate traffic over RoCE
Operations Changing, disabling, change plan, common mistakes

Steps and notes follow the AOS Security Guide (7.3 at the time of writing) and the Nutanix AHV Networking best practice guide.


Understanding Network Segmentation

The problem segmentation solves

One interface or separate lanes Figure 1: Without segmentation, all external CVM traffic shares eth0 and the management VLAN. With it, each type gets its own lane.

Think of eth0 as a single road that every kind of traffic has to use. Administrators reach Prism on it, the nodes copy data to each other on it, iSCSI clients read and write on it, and the DR site receives replication on it. Everything shares one VLAN, one subnet, and the same firewall rules.

That causes two kinds of concern:

  • Security. The management network is usually routed and reachable from many places: jump hosts, monitoring tools, admin workstations. Storage replication and iSCSI traffic don’t need to be reachable from any of them.
  • Traffic separation. A busy iSCSI workload or a large replication job shares the same path as the management traffic. Some customers want them on different VLANs or even different NICs, so one can’t affect the other.

Segmentation gives each traffic type its own lane: a dedicated CVM interface, its own VLAN and subnet, and optionally its own physical NICs.

The CVM interfaces and what they carry

The CVM interfaces and what they carry Figure 2: One interface per traffic type. Management always stays on eth0.

Type CVM interface Host side Subnet Addresses Hypervisors Configured in Prism under
Management eth0 Existing Routable, cluster gateway Existing All Not movable
Backplane eth2 New interface per host (vmk2 on ESXi, br0-backplane on AHV) Non-routable 2 per node AHV, ESXi, Hyper-V Backplane LAN row
Volumes (iSCSI) ntnx0, ntnx1… None Your iSCSI subnet, can be routed to clients At least n+1 AHV, ESXi Create New Interface
Disaster recovery ntnx0, ntnx1… None Routable, with gateway At least n+1 AHV, ESXi Create New Interface or CLI
RDMA rdma0 Host interface on the RDMA network Non-routable 2 per node AHV, ESXi RDMA row

A few things that help when reading this table:

  • Management can’t be moved. It always stays on eth0. Segmentation moves other traffic away from it.
  • eth1 is never involved. It’s the internal link between each CVM and its own host (192.168.5.x).
  • eth2 and rdma0 already exist. AOS creates them during upgrades and leaves them unused until you enable the feature. Never configure or delete them by hand.
  • Service vNICs are named in the order you create them. If you isolate Volumes first, it gets ntnx0, and DR then gets ntnx1. Don’t assume a name from someone else’s design.
  • “n” in “n+1” is the number of nodes. The extra address is for the service’s virtual IP.

Cluster-level and service-level segmentation

The types fall into two families, and the difference explains most of the steps later:

  Cluster-level: backplane and RDMA Service-level: Volumes and DR
What moves The cluster’s own internal traffic The traffic of one service
CVM side eth2 or rdma0 gets an address A new vNIC (ntnx0, ntnx1) is added
Host side Every host gets an interface too Nothing on the host
IPs 2 per node n+1, including a virtual IP
Subnet Non-routable, no gateway Routed if clients or the other site are elsewhere
Configured with A dedicated row in Prism (Backplane LAN, RDMA) Create New Interface, plus feature settings

Logical or physical separation

Logical and physical separation Figure 3: Logical separation uses a new VLAN on the existing NICs. Physical separation adds dedicated NICs.

Every type can be built in one of two ways:

  • Logical (shared uplinks): the segmented traffic gets a new VLAN, but uses the same NICs and bond as management. It needs no new hardware, only the VLAN on the switch trunks. The separation is at Layer 2.
  • Physical (dedicated uplinks): the segmented traffic gets its own virtual switch with its own NICs, usually to its own switch ports. It needs at least two extra NICs per host, connected to two switches for redundancy.

Nutanix recommends a separate VLAN in both cases. Physical separation adds bandwidth isolation on top. Choose it when the customer wants the traffic on different cables, or when replication, live migration or iSCSI traffic is heavy enough to compete with management.

How a CVM interface reaches the network on AHV and ESXi

How a CVM interface reaches the network Figure 4: On AHV, Prism configures the VLAN. On ESXi, you create the port group and the VLAN lives there.

This is the main difference between the hypervisors, and it changes your preparation steps:

  • On AHV, the CVM interface connects to a Nutanix virtual switch (vs0, or a new one such as vs1), which is a bridge with a bond of physical NICs. You choose the virtual switch in the Prism wizard and enter the VLAN ID, and Prism configures the VLAN for you. For backplane, AOS also creates the host’s internal interface automatically.
  • On ESXi, the CVM interface connects to a port group on a standard or distributed vSwitch. Prism can’t create port groups or set VLANs on ESXi hosts. You create the port groups yourself, with the VLAN ID on them, on every host, before running the wizard. For backplane, AOS then creates the vmk2 VMkernel adapter on the host port group you select.

In short: on AHV you prepare at most a virtual switch, and Prism does the rest. On ESXi you prepare port groups for every segmented network.

Routable or non-routable

Type Subnet Why
Backplane Non-routable, no gateway Only CVMs and hosts in the same cluster talk on it. The CVM’s default route stays on eth0, and a gateway on the backplane risks split routing
RDMA Non-routable Only Stargate on the CVMs in the same cluster talks on it
Volumes Routed only if needed Clients in the same subnet connect directly. Clients in other subnets need a client subnet and gateway in the settings
DR Routable, with gateway Replication goes to another site, through routers

What happens when you enable a type

The workflow is the same in principle for every type:

  1. You prepare the switches and the host network.
  2. You fill in the wizard in Prism, and Prism validates the settings before changing anything.
  3. AOS assigns addresses from the subnet or IP pool to every CVM (and every host, for backplane and RDMA).
  4. The CVMs reboot one at a time, so the cluster services move to the new interface. Some types need more than one round of reboots.
  5. You finish with follow-up tasks: restarting Acropolis on AHV for the backplane, moving iSCSI clients for Volumes, reconfiguring remote sites for DR.

Which Segmentation Do You Need?

Nutanix is honest about this: in most cases it recommends the default configuration, with no segmentation of any kind, because it’s simpler to run. Segmentation solves specific problems, so start from the requirement:

Requirement Segmentation type
Keep storage replication, HA and live migration off the management network Backplane
Put replication and live migration on dedicated physical NICs Backplane on a dedicated virtual switch
Give external iSCSI clients (OpenShift, Kubernetes, physical servers, VMs) their own storage network Volumes
Separate production and non-production iSCSI traffic Volumes, two networks
Send replication to the DR site over its own network or WAN link Disaster recovery
Metro Availability over a stretched Layer 2 network Disaster recovery with --stretched_metro
Use RDMA NICs for Stargate-to-Stargate traffic RDMA

They can be combined. A cluster can have a backplane, a Volumes network and a DR network at the same time, each on the existing virtual switch or on its own. When a requirement comes from a security policy, ask which traffic it’s actually meant to protect. Sometimes the concern is iSCSI or DR traffic, not the backplane.


Impact on Each Hypervisor

What each change costs you Figure 5: Only the backplane on AHV, and changing the backplane VLAN, need downtime.

This is the table to show the customer before any change is approved.

Type AHV ESXi
Backplane: enable Guest VMs shut down, all hosts in maintenance mode, rolling CVM reboots Rolling CVM reboots (up to two rounds), guest VMs keep running
Backplane: disable Same downtime procedure Rolling CVM reboots, no cluster downtime
Backplane: change VLAN or subnet backplane_ip_reconfig, cluster stop Same, except not supported on distributed switches
Volumes or DR: enable CVMs reboot several times, one after another Same
Volumes or DR: disable Rolling restart, the service is disrupted until follow-up tasks are done Same
Volumes: after enabling iSCSI clients log out and reconnect to the new virtual IP Same
DR: before enabling or disabling Disable replication schedules running on the hosts Same
RDMA Plan a maintenance window. The guide doesn’t describe guest VM impact Same

Two consequences for planning:

  • Configure one segmentation type at a time. Prism doesn’t let you enable several services at once, and you want to verify each one before adding the next.
  • With several clusters, do them one at a time. Finish, verify, and run NCC on the first before you touch the second.

Prerequisites for Every Type

Item What to check
AOS version 5.5 or later for logical backplane, 5.11 or later for physical backplane, Volumes and DR, 6.6 or later for RDMA with ZTR. Any current release is fine
Cluster health Full NCC run with no failures, data resiliency OK in Prism
VLANs New VLAN IDs, unique in the network, configured on the physical switches first
Proxy ARP Disabled within the Nutanix VLANs
CVM eth2 Not created or configured by hand (KB 9479 and Field Advisory 78 cover removing a manual one)
NSX CVM interfaces not connected to port groups backed by NSX NVDS switches
ESXi switches Standard or distributed, but the same type for all management and backplane traffic in the cluster, not mixed
Dedicated uplinks At least two NICs per host, to two different switches, link up before you start
Reserved ranges None of the segmented subnets overlap 169.254.0.0/16, 192.168.5.0/24, 192.168.7.2/27, 10.100.0.0/16 or 10.200.32.0/24
Prism Central upgrades If the cluster uses a segmented Data Services IP in a secondary subnet, also configure a DSIP in the same subnet as Prism Central, or PC can’t run cluster upgrades
Access IPMI/iLO/iDRAC console access to every host, in case management connectivity breaks

Redundancy matters more once traffic is segmented. Nutanix notes that Stargate doesn’t monitor the health of a segmented network, so with physical segmentation, network failures aren’t tolerated. Every dedicated virtual switch needs two or more uplinks in a fault-tolerant configuration, connected to two separate physical switches.


Common Step 1: Configure the Physical Switches

Do this before anything else in Prism, and test it, for every segmentation type. If the VLAN isn’t on the switch ports, validation will fail, or worse, the CVMs will reboot onto a network where they can’t reach each other.

Add the new VLAN to the trunks that already carry vs0 or vSwitch0 traffic. On NX-OS, for every host-facing port:

interface Ethernet1/1
  switchport trunk allowed vlan add 200

Use add. switchport trunk allowed vlan 200 without add replaces the allowed list, and you’ll cut off management and guest traffic on that port. I’ve seen it happen. Check the result with show interface Ethernet1/1 switchport before moving to the next port.

If the ports are access ports today, they must become trunks first, with the current management VLAN kept as the native (untagged) VLAN. On AHV, changing a host port from access to trunk while the host is using it is a change of its own, and needs its own window.

Configure the new ports as trunks carrying only the segmented VLAN:

interface Ethernet1/21
  description esx01-vmnic2 / ahv01-eth2 backplane
  switchport mode trunk
  switchport trunk allowed vlan 200
  spanning-tree port type edge trunk
  no shutdown

Use the same MTU as the rest of the cluster’s ports. One NIC per host goes to switch A and the other to switch B. Make sure the VLAN is allowed on the inter-switch link (vPC peer link or equivalent), or the two halves of the network can’t reach each other when a host fails over to its other NIC.

Non-routable networks (backplane, RDMA) need no SVI and no gateway. Routed networks (Volumes with remote clients, DR) need a gateway that your network team configures as usual.

Common Step 2: IP Address Pools

Service-specific networks always use an IP pool, which you can create in the Create New Interface wizard. The backplane can use a whole subnet or a pool, but Prism can only create backplane pools from the CLI. To create a pool from any CVM:

network_segmentation --ip_pool_name=BackplanePool --ip_pool_netmask=255.255.255.0 \
  --ip_ranges="[('172.16.200.10', '172.16.200.49')]" ip_pool create

A pool can hold several ranges, all in the same subnet. The same command creates pools for Volumes and DR.

Remember that cluster expansion takes addresses from these pools: two per new node for the backplane, and one per new node for each service-specific network. If a pool is empty, the expansion fails.

If you need specific addresses, for example to match the last octet of the management IPs, AOS supports a custom IP mapping: a JSON file that maps each CVM (and, for the backplane, each host) external IP to its segmented IP from the pool. The Volumes example from the guide, on ESXi:

{
  "svmips": {
    "10.47.240.141": "10.47.6.141",
    "10.47.240.142": "10.47.6.142",
    "10.47.240.143": "10.47.6.143"
  }
}
network_segmentation --service_network --ip_pool=pool1 --desc_name="Volumes Seg 1" \
  --service_name=kVolumes --host_physical_network=dv-volumes-network-1 \
  --service_vlan=151 --ip_map_filepath=/home/nutanix/ip_map.json

For backplane mapping, the JSON also has a hostips section. Follow “Customizing IP Addresses for each CVM and Host” in the Security Guide for the exact backplane command.


Part 1: Backplane Segmentation

What the Backplane Network Is

Nutanix splits the traffic leaving a CVM into two types:

  • Management traffic: Prism, SSH, SNMP, remote syslog, and anything else that isn’t backplane, including communication between user VMs and CVMs (for example iSCSI clients). It uses CVM interface eth0.
  • Backplane traffic: traffic the cluster needs internally: storage RF replication between CVMs, traffic between CVMs and hosts, high availability, and host management. On AHV, VM live migration traffic is backplane too. Once segmentation is enabled, all of it uses CVM interface eth2.

Every CVM already has an eth2. AOS creates it automatically during an upgrade to any version that supports segmentation, and it sits unused until you enable the backplane network. Don’t delete it, and never configure it by hand.

CVM interfaces before and after backplane segmentation Figure 6: Without segmentation everything leaves through eth0. With it, internal traffic moves to eth2 on its own VLAN.

When you enable the backplane LAN, AOS:

  1. Gives every CVM eth2 an address from the backplane subnet.
  2. Creates a backplane interface on every host and gives it an address from the same subnet. On ESXi this is a new VMkernel adapter (vmk2). On AHV it’s an internal interface on the selected virtual switch (br0-backplane when it’s on br0).
  3. Moves the cluster services to the new network through rolling CVM reboots.

That’s why the guide says you need two IP addresses per node: one for the CVM and one for the host.


Shared and dedicated uplink designs on AHV and ESXi Figure 7: Logical segmentation shares the existing uplinks. Physical segmentation gives the backplane its own.

  Shared uplinks (logical) Dedicated uplinks (physical)
Where the backplane lives New VLAN on the existing vs0 / vSwitch0 New VLAN on a new virtual switch with its own NICs
Extra NICs needed No Yes, at least two per host, to two switches
Host preparation on AHV None Remove uplinks from vs0, create vs1
Host preparation on ESXi Two port groups on vSwitch0 New vSwitch, two port groups
Separation Logical, by VLAN Physical, by NIC and VLAN
Minimum AOS 5.5 5.11

In both designs, Nutanix strongly recommends a separate VLAN for the backplane. You can leave the VLAN ID empty, but the backplane then lands on the default (untagged) VLAN of the switch, and you’ve gained very little.

A naming warning before we go further. On an AHV host, the physical NICs are called eth0, eth1, eth2, and so on. The CVM also has an eth2. They’re different things. In this post, “host NICs” means physical ports, and “CVM eth2” means the CVM’s backplane vNIC.


Backplane Downtime on Each Hypervisor

The backplane is the one type where AHV and ESXi behave very differently, so it’s worth looking at in detail.

  AHV ESXi
Guest VMs Must be shut down for the whole procedure Keep running
Hosts All hosts in maintenance mode No host maintenance mode
CVMs Rolling reboots Rolling reboots, up to two rounds
Extra steps Restart Acropolis cluster-wide, exit maintenance mode None
Disabling later Same downtime procedure Rolling, no cluster downtime

The AHV procedure starts with “shut down all the guest VMs in the cluster” and puts every AHV host into maintenance mode before the backplane is configured. It applies to both AHV designs: the guide sends the logical (VLAN-only) case on AHV to the same procedure as the physical one.

On ESXi, the guest VMs keep running while the CVMs reboot one at a time. The guide notes that the change can take up to two rolling reboots. The first moves each CVM’s eth2 to the selected port group, and only happens where it isn’t already there. The second moves the cluster services to the new interface.

One consequence that’s easy to forget:

  • Prism Central, Files, Objects and other Nutanix service VMs on an AHV cluster are guest VMs too. They go down with everything else. Shut them down with their own procedures, not with a hard power-off, and expect Prism Central to be unavailable during the window if it runs on this cluster.
    • *

Backplane Subnet and IP Plan

Choosing the subnet

The backplane subnet has three rules:

  1. Non-routable, with no gateway. The CVM’s default route stays on eth0, and there’s no route on the backplane interface. If you pick a routable subnet, you risk split routing. Nutanix recommends a non-routable subnet only.
  2. Big enough for the future. Two addresses per node. Changing the subnet later uses backplane_ip_reconfig, which stops the cluster. Size it for the maximum the cluster could grow to, not for today.
  3. Avoid reserved ranges. Don’t use 169.254.0.0/16 (APIPA), 192.168.5.0/24 (internal CVM to host), 192.168.7.2/27 (cross-cluster TCP proxy), or 10.100.0.0/16 and 10.200.32.0/24 (Objects internal services).

If you don’t want to give a whole subnet to the backplane, create a backplane IP pool from the CLI (Common Step 2) with only the ranges you want to use. Prism Element can’t create backplane pools, only service-specific ones.

Example IP plan

For a 4-node cluster with management on 10.10.10.0/24 (VLAN 100) and the backplane on VLAN 200:

Item Value
Backplane VLAN 200, tagged
Backplane subnet 172.16.200.0/24, no gateway
Addresses used 8 (2 per node), plus room for every future node
CVM eth2 addresses Assigned by AOS from the subnet or pool
Host backplane addresses Assigned by AOS from the subnet or pool

AOS assigns the addresses itself. In the guide’s own example, CVMs and hosts alternate (.1 CVM, .2 host, .3 CVM, .4 host). If you need specific addresses, use the custom IP mapping described in Common Step 2.


Backplane on AHV

AHV backplane segmentation procedure Figure 8: The AHV procedure. Everything from step 3 to step 8 is inside the downtime window.

Skip this step for the shared uplink design. The backplane will go on vs0.

For dedicated uplinks, the host NICs for the backplane must leave vs0 and join a new virtual switch:

  1. In Prism Element, go to Settings > Network Configuration > Virtual Switch.
  2. Edit vs0 and remove the NICs you’ll use for the backplane from its uplinks on every host. Keep at least two NICs in vs0.
  3. Create a new virtual switch, for example vs1:
    • Name and description: vs1, “Backplane”
    • MTU: the same as the switch ports
    • Bond type: Active-Backup. The AHV networking guide asks for redundant adapters of at least 10 Gbps with a fault-tolerant load balancing algorithm.
    • Uplinks: the backplane NICs on every host
  4. Check that the uplinks are up on every host before you continue. The guide states this as a requirement.

From a CVM, you can check the result:

acli net.list_virtual_switch
manage_ovs show_uplinks

Prism applies virtual switch changes host by host. I prefer doing this preparation as its own change, a day or more before the backplane window. Then, if something goes wrong with the uplinks, you’re not troubleshooting it inside a downtime window.

A2: Shut Down the Guest VMs

Shut down every guest VM from inside the guest OS, or from Prism. That includes Nutanix service VMs, each with its own procedure:

  • Prism Central on this cluster: shut it down cleanly. You’ll work only in Prism Element during the window.
  • Nutanix Files: stop the file server properly before powering off the FSVMs.
  • Any other appliance (backup proxies, Objects, NKP nodes): stop them the way their own documentation describes.

Record which VMs were running, so you power on exactly the same set at the end.

acli vm.list power_state=on

A3: Put All AHV Hosts in Maintenance Mode

From any CVM, list the hosts:

acli host.list

Put each AHV host into maintenance mode. Never the CVMs:

acli host.enter_maintenance_mode 10.10.10.21
acli host.enter_maintenance_mode 10.10.10.22
acli host.enter_maintenance_mode 10.10.10.23
acli host.enter_maintenance_mode 10.10.10.24

Each one should return EnterMaintenanceMode: complete. Then verify every host:

acli host.get 10.10.10.21

Look for node_state: "EnteredMaintenanceMode" and schedulable: False. Don’t continue if any node failed to enter maintenance mode. If HA reservation is enabled, check it first under Settings > Manage VM High Availability, because the guide notes nodes can’t enter maintenance mode while it’s on. Turn it back on at the end.

Never use this procedure on a single-node cluster.

A4: Enable the Backplane LAN in Prism

  1. In Prism Element, click the gear icon and open Network Configuration.
  2. On the Internal Interfaces tab, in the Backplane LAN row, click Configure.
  3. Fill in the dialog:
Field Shared uplinks Dedicated uplinks
Subnet IP 172.16.200.0 172.16.200.0
Netmask 255.255.255.0 255.255.255.0
VLAN ID 200 200
Virtual Switch vs0 vs1

Then click Verify and Save.

Prism validates the settings first. If validation passes, it creates the backplane network, and the CVMs reboot one at a time. Follow the progress on the Tasks page and don’t touch anything until the task completes.

A5: Restart Acropolis Cluster-Wide

When the task has completed, SSH to any CVM and run:

allssh genesis stop acropolis
cluster start

Then check that every service is up:

cluster status | grep -v UP

If Prism showed “Failed to restart one or more services after Backplane was enabled”, the guide says the segmentation task itself completed, but some services didn’t start in time. Run cluster start and check again.

A6: Exit Maintenance Mode and Power On

For each host:

acli host.exit_maintenance_mode 10.10.10.21
acli host.get 10.10.10.21

Check for node_state: "AcropolisNormal" (or kAcropolisNormal) and schedulable: True.

Before powering on the guest VMs, run the verification in the section below. If the backplane isn’t healthy, you want to know now, while nothing is running. Then:

  1. Turn HA reservation back on if you turned it off.
  2. Power on Prism Central and the Nutanix service VMs first, then the guest VMs, in the customer’s usual order.

Backplane on ESXi

ESXi backplane segmentation procedure Figure 9: The ESXi procedure. Guest VMs keep running throughout.

On ESXi, Prism can’t create VLANs or port groups on the hosts. The VLAN for the backplane lives on the ESXi port groups, and you create them yourself before running the wizard. Prism creates the VMkernel adapter (vmk2) on the host port group for you. Don’t create it by hand.

Create two port groups on vSwitch0 on every host, with identical names and the backplane VLAN:

Port group Used for VLAN
Backplane-CVM CVM eth2 200
Backplane-Host Host vmk2, created by Nutanix 200

With standard vSwitches, you can do it on all hosts at once from a CVM:

hostssh "esxcli network vswitch standard portgroup add -p Backplane-CVM -v vSwitch0; \
esxcli network vswitch standard portgroup set -p Backplane-CVM --vlan-id 200; \
esxcli network vswitch standard portgroup add -p Backplane-Host -v vSwitch0; \
esxcli network vswitch standard portgroup set -p Backplane-Host --vlan-id 200"

Check:

hostssh "esxcli network vswitch standard portgroup list | grep -i backplane"

With a vSphere Distributed Switch, create the two distributed port groups once in vCenter with VLAN 200.

The guide also allows leaving the port group fields empty in the wizard, so Prism picks the default port group on vSwitch0. I prefer creating them explicitly. On ESXi the VLAN has to live on a port group, and named port groups make it obvious in vCenter what they’re for.

For dedicated uplinks, on every host:

  1. Create a new vSwitch, for example vSwitch1.
  2. Remove the backplane NICs (for example vmnic2 and vmnic3) from vSwitch0.
  3. Add them to vSwitch1, one active and one standby, or both active.
  4. Create Backplane-CVM and Backplane-Host on vSwitch1, both with VLAN 200.

The esxcli equivalent, one host at a time:

esxcli network vswitch standard add -v vSwitch1
esxcli network vswitch standard uplink remove -u vmnic2 -v vSwitch0
esxcli network vswitch standard uplink remove -u vmnic3 -v vSwitch0
esxcli network vswitch standard uplink add -u vmnic2 -v vSwitch1
esxcli network vswitch standard uplink add -u vmnic3 -v vSwitch1
esxcli network vswitch standard policy failover set -v vSwitch1 -a vmnic2 -s vmnic3
esxcli network vswitch standard portgroup add -p Backplane-CVM -v vSwitch1
esxcli network vswitch standard portgroup set -p Backplane-CVM --vlan-id 200
esxcli network vswitch standard portgroup add -p Backplane-Host -v vSwitch1
esxcli network vswitch standard portgroup set -p Backplane-Host --vlan-id 200

Before you remove any NIC from vSwitch0, check that it isn’t the only active uplink for management or the CVM port group. If you override the failover order on the port groups, the guide asks that each port group keeps at least one uplink in its Active list.

Don’t mix switch types. All management and backplane traffic in a cluster must be on standard vSwitches, or all on distributed vSwitches, with the same port group type (normal or NSX segment) on every node.

E2: Enable the Backplane LAN in Prism

  1. In Prism Element, click the gear icon and open Network Configuration.
  2. On the Internal Interfaces tab, in the Backplane LAN row, click Configure.
  3. Fill in the dialog:
Field Value
Subnet IP 172.16.200.0
Netmask 255.255.255.0
VLAN ID 200, matching the port groups
Host Port Group Backplane-Host
CVM Port Group Backplane-CVM

Then click Verify and Save.

After validation, the CVMs reboot in a rolling fashion, up to two rounds. Guest VMs keep running. Follow the progress on the Tasks page. When it’s done, every host has a new vmk2 on Backplane-Host.

E3: vSphere HA with Distributed Switches

The guide has a specific warning for ESXi clusters with a distributed switch and segmentation enabled. If the management network goes down, ESXi might trigger HA host isolation response and restart all VMs. To avoid it, configure multiple isolation addresses with the das.isolationaddress advanced option in vCenter.

It’s worth reviewing the HA isolation settings on standard switches too, while you’re there.


Verifying the Backplane

Run these from any CVM after the task completes.

1. Segmentation status:

network_segment_status

It should report that network segmentation is enabled.

2. Backplane addresses of the CVMs and hosts:

svmips -b
hostips -b

These must show the backplane addresses (172.16.200.x), different from the output of svmips and hostips without -b. If they’re the same, the cluster isn’t using the backplane.

3. The CVM interfaces:

allssh "ip -br addr show eth2"

Every CVM should show eth2 up with its backplane address.

4. The host interfaces:

# AHV
hostssh "ip -br addr | grep -i backplane"

# ESXi
hostssh "esxcli network ip interface ipv4 get | grep vmk2"

5. Reachability across the backplane, from one CVM to the backplane address of every other CVM and host:

for ip in $(svmips -b) $(hostips -b); do
  ping -c 2 -W 1 $ip > /dev/null && echo "$ip OK" || echo "$ip FAILED"
done

6. Services and health:

cluster status | grep -v UP
ncc health_checks run_all

7. On AHV, test a live migration of a test VM between two hosts. Live migration now runs over the backplane, so this proves the backplane works host to host, not only CVM to CVM.

Keep the output of steps 1 to 5 for the change record. It’s the proof that the change did what it was supposed to do.


Backplane Day 2 Operations

Cluster expansion

  • Each new node takes two addresses from the backplane subnet or pool. If there aren’t enough, the expansion task fails, and you add ranges to the pool first.
  • The switch ports of the new node must be configured exactly like the existing ones, with the same backplane VLAN. Otherwise the expansion fails at network validation.
  • On AHV with dedicated uplinks, prepare the new host’s virtual switch the same way. On ESXi, create the same port groups with the same names before you expand.

AOS upgrades

The upgrade notes in the Security Guide only cover clusters coming from AOS versions without segmentation support, where eth2 is created automatically during the upgrade. For a segmented cluster, the rule is simple: eth2 on every CVM belongs to AOS and should never be touched by hand. That includes hardening scripts that “clean up unused interfaces”. Run NCC before and after every upgrade as usual.

Changing the VLAN or subnet later

backplane_ip_reconfig --backplane_vlan=300 --backplane_ip_pool=NewBackplanePool

This command does a cluster stop, even if you only change the VLAN, so it means cluster downtime. During the run you might see “Failed to reach a node”. The guide says to ignore it and not stop the script. Afterwards, verify with svmips -b and hostips -b.

backplane_ip_reconfig isn’t supported on ESXi clusters with distributed switches. There, you disable segmentation and enable it again with the new subnet or VLAN.

Disabling segmentation (the rollback)

  • ESXi: from any CVM, run network_segmentation --backplane_network --disable and confirm with Y. The CVMs restart one at a time, with no cluster downtime. Confirm with network_segment_status, and check that svmips and svmips -b now show the same addresses.
  • AHV: the same downtime procedure as enabling it. Shut down the guest VMs, put all hosts into maintenance mode, click Disable in the Backplane LAN row, run allssh genesis stop acropolis and cluster start, exit maintenance mode, and power the VMs back on.

Write the rollback into the change request. On AHV, a rollback is a second downtime window, and the customer should know that before approving the first one.




Part 2: Volumes (iSCSI) Isolation

Nutanix Volumes presents volume groups over iSCSI to clients outside the cluster: physical servers, VMs on other platforms, and Kubernetes or OpenShift nodes through the Nutanix CSI driver. By default, those clients connect to the cluster Data Services IP (DSIP), which lives on the management network and is served by CVM eth0. Volumes isolation gives iSCSI its own VLAN, its own CVM vNIC, and its own target address.

The iSCSI path before and after Figure 10: Before, clients use the DSIP on the management network. After, they use the Volumes virtual IP on the iSCSI VLAN.

What changes, and what doesn’t

  • A new vNIC on every CVM, named ntnx0 (or the next free name), with an address from the IP pool.
  • A new target address, the Volumes virtual IP, also from the pool. Clients discover and log in to this address instead of the DSIP.
  • No host interface. Nothing new on AHV or ESXi hosts except the virtual switch or port group you prepare.
  • Existing sessions don’t move by themselves. The DSIP keeps working until you move every client.
  • Guest VMs keep running on both hypervisors. The CVMs reboot several times, one after another.

When to use it

  • External iSCSI clients that should not reach the management network, which is the most common reason.
  • OpenShift or Kubernetes clusters using the Nutanix CSI driver with volume groups.
  • Separating production and non-production iSCSI. You can create up to two Volumes networks per cluster, each with its own VLAN, pool and virtual IP.

Design options

Volumes on shared or dedicated uplinks Figure 11: The same two designs as the backplane, but with only one CVM port group on ESXi.

  Shared uplinks Dedicated uplinks
AHV Select vs0 and enter the iSCSI VLAN in the wizard Create vs2 with its own NICs, select it in the wizard
ESXi Create a Volumes-CVM port group with the iSCSI VLAN on vSwitch0 Create vSwitch1 with its own NICs and the Volumes-CVM port group on it

Planning the network

Example for a 4-node cluster:

Item Example
iSCSI VLAN 300
iSCSI subnet 10.30.0.0/24, gateway 10.30.0.1 if clients are in other subnets
IP pool 10.30.0.41 to 10.30.0.60: 4 CVMs + 1 virtual IP + room for growth
Virtual IP 10.30.0.50, picked from the pool
Clients in the same subnet OpenShift workers with an interface in 10.30.0.0/24
Clients in other subnets 10.40.0.0/24, entered as a client subnet with the gateway

Clients in other subnets Figure 12: Clients in the iSCSI subnet connect directly. Clients elsewhere need the client subnet and gateway settings.

Two practical points from my OpenShift project:

  • Give the clients an interface in the iSCSI subnet when you can. Direct Layer 2 access is simpler and avoids pushing iSCSI through a router or firewall.
  • Talk to the client teams early. Every client must log out and reconnect, and for Kubernetes the target address lives in the CSI configuration. That’s usually the longest part of the project, not the Nutanix change.

The workflow

Volumes or DR isolation workflow Figure 13: The same workflow serves Volumes and DR. Only the settings and follow-up tasks differ.

Volumes on AHV

V1: Configure the switch ports

Add VLAN 300 to the host trunks (shared uplinks), or configure the new ports (dedicated uplinks), as described in Common Step 1. If clients are in other subnets, ask the network team for the gateway on VLAN 300 and routing to the client subnets.

For shared uplinks, skip this step. The vNIC will go on vs0.

For dedicated uplinks:

  1. In Prism Element, go to Settings > Network Configuration > Virtual Switch.
  2. Edit vs0 and remove the NICs you’ll dedicate to iSCSI from its uplinks on every host.
  3. Create a new virtual switch, for example vs2, with those NICs as uplinks, MTU matching the switch ports, and a fault-tolerant bond such as Active-Backup.
  4. Check that the uplinks are up on every host:
acli net.list_virtual_switch
manage_ovs show_uplinks

V3: Create the interface

  1. In Prism Element, click the gear icon and open Network Configuration.
  2. On the Internal Interfaces tab, click Create New Interface.
  3. On the Interface Details tab:
Field Value
Name Volumes-Prod
VLAN ID 300
Bridge vs0 (shared) or vs2 (dedicated)
IP pool Create New IP Pool: name Volumes-Pool, netmask 255.255.255.0, range 10.30.0.41 to 10.30.0.60, then Save and select it
  1. Click Next.

V4: Feature selection

On the Feature Selection tab, select Volumes and fill in:

Setting Value Notes
Virtual IP 10.30.0.50 Optional, but set it. Otherwise AOS picks a random address from the pool
Client subnet 10.40.0.0/24 Only for clients outside 10.30.0.0/24. Prism accepts one
Gateway 10.30.0.1 Required if you set a client subnet

Click Save, then Save again in the Create Interface dialog.

V5: Wait for the rolling reboots

The CVMs reboot several times, one after another, and other tasks may start. Follow them on the Tasks page and don’t start anything else until they’re all complete. Guest VMs keep running.

Then continue with the client migration and verification below, which are the same on both hypervisors.

Volumes on ESXi

VE1: Configure the switch ports

Same as V1.

VE2: Create the CVM port group

On ESXi, you create one port group for the CVMs, with the iSCSI VLAN. No host port group is needed, because no VMkernel adapter is created for Volumes.

Shared uplinks, on every host at once from a CVM:

hostssh "esxcli network vswitch standard portgroup add -p Volumes-CVM -v vSwitch0; \
esxcli network vswitch standard portgroup set -p Volumes-CVM --vlan-id 300"

Dedicated uplinks, one host at a time:

esxcli network vswitch standard add -v vSwitch1
esxcli network vswitch standard uplink remove -u vmnic2 -v vSwitch0
esxcli network vswitch standard uplink remove -u vmnic3 -v vSwitch0
esxcli network vswitch standard uplink add -u vmnic2 -v vSwitch1
esxcli network vswitch standard uplink add -u vmnic3 -v vSwitch1
esxcli network vswitch standard policy failover set -v vSwitch1 -a vmnic2 -s vmnic3
esxcli network vswitch standard portgroup add -p Volumes-CVM -v vSwitch1
esxcli network vswitch standard portgroup set -p Volumes-CVM --vlan-id 300

With a distributed switch, create the Volumes-CVM distributed port group once in vCenter with VLAN 300. Don’t mix standard and distributed switches in the same cluster.

Check the result:

hostssh "esxcli network vswitch standard portgroup list | grep -i volumes"

VE3: Create the interface

Same as V3, with one difference in the Interface Details tab:

Field Value
Name Volumes-Prod
CVM Port Group Volumes-CVM
IP pool Volumes-Pool, 10.30.0.41 to 10.30.0.60

The VLAN comes from the port group. Then do the feature selection (V4) and wait for the rolling reboots (V5), exactly as on AHV.

Move the iSCSI clients to the new network

Enabling the network doesn’t move existing sessions. Clients stay connected to the DSIP on eth0 until you move them. Both paths work at the same time, but Nutanix recommends moving every client for real isolation. Do it client by client, in each application’s maintenance window.

Step 1: Log out. On each client, log out of all iSCSI targets that use the DSIP or CVM eth0.

Step 2: Clean up discovery (optional). Remove the discovery records for the DSIP.

Step 3: Update the allowlist. If volume groups allow clients by IP address and the client’s IP changes (because it now uses an interface in the iSCSI VLAN), run from any CVM:

acli vg.detach_external <vg_name> initiator_network_id=<old_client_ip>
acli vg.attach_external <vg_name> initiator_network_id=<new_client_ip>

Step 4: Reconnect. Discover the Volumes virtual IP and log in to the targets. On a Linux client:

iscsiadm -m discovery -t sendtargets -p 10.30.0.50:3260
iscsiadm -m node -p 10.30.0.50:3260 --login
iscsiadm -m session

For Kubernetes or OpenShift with the Nutanix CSI driver, the target address also lives in the storage configuration. My OpenShift post covers that case step by step.

Adding client subnets later

Prism takes one client subnet. To add more, use the CLI from any CVM:

network_segmentation --service_network --update --interface="ntnx0" \
  --service_name="kVolumes" --client_subnets="10.40.0.0/24,10.41.0.0/24"

The list replaces the existing one, so always include the subnets you already have.

A second Volumes network

To separate production and non-production iSCSI, repeat the steps with a second VLAN, pool and virtual IP after the first network is complete. It gets the next free vNIC name, for example ntnx1. Two is the maximum for Volumes.

Verify Volumes isolation

# The vNIC is up with an address from the pool on every CVM
allssh "ip -br addr show ntnx0"

# The CVMs reach each other on the iSCSI network
ping -c 2 -I ntnx0 10.30.0.42

Then check:

  • The Internal Interfaces tab shows the interface enabled, with the virtual IP.
  • Each client lists sessions to 10.30.0.50 only (iscsiadm -m session on Linux).
  • No client is still logged in through the DSIP.
  • A full NCC run is clean.

Limitations

  • With Volumes segmentation enabled, volume group attachments aren’t recovered during VM recovery. Plan your DR runbooks accordingly.
  • Objects worker nodes keep using CVM eth0 for iSCSI. Other external clients, such as Files, use the new interface.
  • If the cluster’s only DSIP is in a segmented secondary subnet, add a DSIP in the Prism Central subnet, or Prism Central can’t run cluster upgrades.

Rolling back Volumes isolation

  1. In Network Configuration > Internal Interfaces, click Disable for the Volumes interface. The cluster does a rolling restart, and iSCSI through the virtual IP stops working.
  2. Move every client back: log out of the targets on the virtual IP, remove its discovery records, discover the cluster DSIP, and log in again.

Schedule the rollback like the original change, with the client teams ready.


Part 3: Disaster Recovery Isolation

DR isolation moves replication between sites off eth0 and onto its own VLAN and vNIC. It applies to protection domains in Prism Element and to Nutanix DR in Prism Central, and to every schedule type: asynchronous, NearSync, synchronous and Metro Availability.

DR isolation between two sites Figure 14: Each site replicates from its DR interface, through a routed path. Management stays separate.

Prerequisites specific to DR

  • The DR VLAN and subnet must be routable, with a gateway, because replication goes to another site.
  • The pool needs n+1 addresses, the extra one for the DR virtual IP.
  • Enable DR segmentation at both sites before you configure the remote sites.
  • Disable the replication schedules running on the hosts before enabling or disabling DR segmentation.
  • Firewalls between the sites must allow replication between the DR subnets of both sites, not only between their management subnets.

Steps on AHV and ESXi

The steps are the same as for Volumes, with the DR VLAN and pool:

  1. Switch ports: add the DR VLAN to the trunks or configure the dedicated ports. Make sure the gateway and routing to the other site exist.
  2. Host network: on AHV, use vs0 or a dedicated virtual switch. On ESXi, create a DR-CVM port group with the DR VLAN on every host.
  3. Create New Interface: name (DR-Replication), VLAN ID (AHV) or CVM port group (ESXi), and a new pool with n+1 addresses or more.
  4. Feature Selection: select Disaster Recovery and fill in the settings below.
  5. Wait for the rolling CVM reboots.
  6. Repeat at the other site.
Setting What it does
Virtual IP Optional. The DR address of the cluster. For Prism Central-based Nutanix DR, it must be different from the cluster external IP and the Data Services IP
Gateway The gateway of the DR subnet

Protection domains: reconfigure the remote sites

With Prism Element protection domains, configure the remote sites at both locations after enabling segmentation, and again if you disable it later.

There’s a catch the guide calls out: after segmentation, the remote site allows only the virtual IP by default, so traffic from the other CVM addresses in the pool can be blocked, and replication fails. Configure the firewall rules to allow the required ports for all addresses in the segmentation pool. KB-19733 has the details.

Prism Central-based Nutanix DR

The Nutanix DR guide has its own “Network Segmentation” section, which applies to protection policies and recovery plans. One limit to plan around: Prism Central can’t configure DR segmentation without a gateway. If you need that, use the CLI.

Metro on a stretched Layer 2 network

For Metro Availability between sites in the same broadcast domain, you can create the DR network without a gateway, from the CLI only, with --stretched_metro. First create the DR IP pool (Common Step 2), then on AHV:

network_segmentation --service_network --service_name=kDR --ip_pool=DR_pool \
  --service_vlan=124 --desc_name="L2 Stretch for AHV" --host_virtual_switch=vs0 \
  --stretched_metro

On ESXi, the same command takes the CVM port group instead of the virtual switch:

network_segmentation --service_network --service_name=kDR --ip_pool=DR_pool \
  --service_vlan=124 --desc_name="L2 Stretch for ESXi" --host_physical_network=portgroup0 \
  --stretched_metro

Without a gateway, DR is limited to clusters in the same Layer 2 domain. Check the AOS release notes for the minimum version that supports this.

Verify DR isolation

  • allssh "ip -br addr show ntnx1" shows the DR vNIC up on every CVM (use the name your interface got).
  • The remote site shows as connected at both sites.
  • A test replication completes, and its traffic is visible on the DR VLAN, not on management.
  • A full NCC run is clean at both sites.

Part 4: RDMA Network Segmentation

RDMA network between nodes Figure 15: Stargate on each CVM talks to the other nodes over RoCE, on a dedicated RDMA NIC and VLAN.

RDMA segmentation applies to clusters with RDMA-capable NICs (NVIDIA Mellanox ConnectX family). Stargate-to-Stargate traffic between CVMs then runs over RoCE on a separate RDMA LAN, through a CVM interface called rdma0 that AOS creates during upgrades. It’s supported on AHV and ESXi.

Requirements

  • At least two RDMA-enabled NICs in every node. If any node is missing them, the RDMA option is disabled.
  • No mixed NIC families on the same node, such as CX-4 with CX-5, or CX-5 NICs of different speeds.
  • Uniform configuration. Every node must have RDMA port pass-through or Zero Touch RoCE configured the same way. A mix isn’t supported.
  • A non-routable subnet, two addresses per node, sized for expansion, and a VLAN configured on the switch ports.
  • For Zero Touch RoCE (ZTR): ConnectX-5 or ConnectX-6 NICs, the same NIC firmware on all nodes (NCC checks it, see KB 4289), and AOS 6.6 or later.
  • Without ZTR: the switches need Priority Flow Control (PFC) configured as described in the guide’s PFC specifications.

Procedure

  1. In Prism Element, open Settings > Network Configuration > Internal Interfaces. Prism shows the RDMA row only when it detects ConnectX-5 or ConnectX-6 NICs.
  2. Click Configure in the RDMA row.
  3. Enter a non-routable Subnet IP and Netmask, and the VLAN ID. The VLAN is optional with ZTR, but Nutanix recommends it.
  4. Select Use Zero Touch RoCE, or the PFC value configured on the physical switch ports. Selecting ZTR disables the PFC field.
  5. Click Verify and Save.
  6. If RDMA port pass-through wasn’t set up during Foundation and the cluster runs AHV, Prism asks you to choose the port. Click Next, select the port to reserve for RDMA on all hosts, and click Save. If pass-through was set up in Foundation, the port is fixed and can’t be changed here.

The guide doesn’t describe the impact on running VMs for this change, so plan it in a maintenance window.

iSER

On AHV, RDMA-capable clusters can also use iSER (iSCSI Extensions for RDMA) between the AHV host and the CVM. AHV Turbo is the iSER initiator, and Stargate is the target. It reduces latency and CPU use for guest VM I/O, and falls back to TCP without disruption if RDMA fails. iSER uses fixed internal IP addresses that can’t be changed, and has its own NIC matrix and CVM memory requirements. Treat it as a performance feature rather than a segmentation design, and follow the iSER section of the Security Guide if you need it.


Operations

Changing, Disabling and Deleting a Volumes or DR Network

  • Change the VLAN or pool: there’s no edit. You disable the interface and create it again with the new settings. If its name (for example ntnx0) is still free, AOS reuses it. If another service took it, the service gets a new one, such as ntnx1.
  • Disable: in Network Configuration > Internal Interfaces, click Disable for the interface. The cluster does a rolling restart and the service is disrupted until you finish the follow-up. The IP pool stays available.
  • Follow-up after disabling Volumes: move the clients back to the DSIP, as described in Part 2.
  • Follow-up after disabling DR: reconfigure the remote sites at both locations.
  • Delete the vNIC: disabling doesn’t remove the vNIC, so AOS can reuse it later. To delete it, first check the vNIC hot-unplug limitations in the AHV Admin Guide, then run the command below from any CVM.
network_segmentation --service_network --interface="ntnx0" --delete

For the backplane, changing, disabling and expanding are covered in Part 1.

A Change Plan Template

This is the structure I use. Run it once per segmentation type and once per cluster, never several at the same time.

Phase Task Applies to Impact
Before Agree VLANs and subnets with the network team (non-routable for backplane and RDMA, routed for DR) All None
Before Add the VLAN to switch trunks with add, or cable and configure new ports All None if done carefully
Before NCC run, data resiliency OK, console access tested on every host All None
Before Create vs1/vs2 on AHV, or port groups and vSwitches on ESXi All Low
Before Create IP pools, at least n+1 (services) or 2 per node (backplane, RDMA) All None
Before Disable running replication schedules DR Replication paused
Window Shut down Prism Central, service VMs, and guest VMs, then all hosts into maintenance mode Backplane on AHV Downtime starts
Window Configure the network in Prism and wait for the rolling CVM reboots All Backplane on AHV: downtime. Others: none
Window genesis stop acropolis, cluster start, exit maintenance mode, power on Backplane on AHV Downtime ends
Window Move iSCSI clients to the Volumes virtual IP Volumes Short I/O pause per client
Window Reconfigure remote sites at both locations, allow the pool in the firewall DR (protection domains) Replication resumes
After Verification commands, full NCC, change record with outputs All None
After Re-enable replication schedules and HA reservation DR, backplane on AHV None

Common Mistakes

Symptom Likely cause
Management lost on a host after the switch change switchport trunk allowed vlan used without add
Validation fails in Prism VLAN not on the switch ports, or a dedicated uplink is down
AHV host won’t enter maintenance mode HA reservation enabled, or a VM still running that can’t be migrated
CVMs can’t reach each other after the reboots VLAN missing on the inter-switch link or on one switch
Asymmetric routing or odd reachability problems A routable subnet with a gateway used for the backplane
Expansion fails at network validation New node’s switch ports missing a segmented VLAN
Expansion fails on IP allocation A backplane or service pool out of addresses
Segmentation refuses to enable A manually configured CVM eth2, or NSX NVDS port groups
“Failed to restart one or more services” Services slow to start after the backplane change. Run cluster start
iSCSI still on the management network after Volumes isolation Clients never logged out of the DSIP and reconnected to the new virtual IP
Routed iSCSI clients can’t connect Client subnet or gateway not set in the Volumes settings
Replication fails after DR isolation Remote sites not reconfigured, or the firewall allows only the virtual IP and not the whole pool
DR segmentation can’t be created from Prism Central No gateway. Use the CLI
RDMA row missing in Prism A node without two RDMA NICs, or mixed NIC families
Prism Central can’t upgrade the cluster Only a segmented DSIP in a secondary subnet, with no DSIP in the Prism Central subnet

Conclusion

Network segmentation isn’t hard to configure. Each dialog in Prism has a handful of fields. What makes it a real project is everything around those dialogs: the right subnet for each type, the VLAN on every switch port and inter-switch link, the port groups on ESXi, the virtual switches on AHV, the follow-up for iSCSI clients and remote sites, and above all the downtime window that the backplane needs on AHV.

If I had to keep only five points from this post:

  1. Start from the requirement. Backplane, Volumes, DR and RDMA solve different problems, and the default with no segmentation is still Nutanix’s recommendation when there’s no requirement.
  2. On AHV, the backplane needs a full guest VM shutdown, to enable it and to roll it back. Everything else is rolling CVM reboots.
  3. Non-routable for backplane and RDMA, routed for DR. Volumes can be either, with client subnets for routed clients.
  4. The work isn’t done when Prism says the task succeeded. iSCSI clients must reconnect, remote sites must be reconfigured, and firewalls must allow the whole pool.
  5. Prove it before you hand it over. svmips -b, hostips -b, ping sweeps, iSCSI sessions on the new virtual IP, a test replication, a live migration test on AHV, and a clean NCC, all in the change record.

Steps in this post follow the Nutanix AOS Security Guide 7.3 and the AHV Networking best practice guide as of November 2026. Check the guide for your AOS version before the change, because procedures and requirements can change between releases.